SEMCO
Get a Quote

Heat transfer · Free tool

Batch heating and cooling time calculator

Estimate how long a jacketed reactor or tank takes to heat or cool a batch, with steam or with a liquid medium, and how much steam it uses.

MinuteskWhSteam kg

1. Batch

kg
kJ/kg·K

Water 4.18, aqueous solutions 3.5–4, organics 1.8–2.5

2. Heating or cooling medium

3. Heat transfer

W/m²·K

Jacketed SS vessel 300–600, glass-lined 200–350, coil 500–900

m²

Heating time

45.6min

Heat duty per batch

291.7kWh

Average heat rate

384.1kW

Details
UA4.8 kW/K
Steam temperature143.7 °C
Steam consumed (excluding losses)492.2 kg per batch
Average steam rate648.1 kg/h
Assumes a well-mixed batch, constant U and no heat losses or reaction heat. Add 10–20% for losses and for U falling as the jacket fouls.

Want these numbers checked?

Send them to a SEMCO process engineer for a free review, sizing and budget price.

Discuss on WhatsApp

How this calculator works

For condensing steam, the jacket stays at the steam's saturation temperature, so the batch approaches it exponentially: time = (M·cp ÷ U·A) × ln((Ts − t1) ÷ (Ts − t2)).

For a liquid medium such as cooling water or thermic fluid, its temperature changes through the jacket. The calculator uses Kern's method for a well-mixed batch with a non-isothermal medium.

Formulas used

Isothermal medium (steam)

θ=McpUAlnTs−t1Ts−t2

Non-isothermal medium (Kern)

θ=Mcpwc·KK−1lnT1−t1T1−t2, K=eUA/wc

Assumptions and limits

  • Well-mixed batch with constant properties and constant U.
  • No heat losses, no reaction heat and no phase change in the batch.
  • Use the wetted area at your working level; U values in the hint are typical for agitated vessels.

Worked example

5,000 kg batch (cp 3.5 kJ/kg·K) heated from 30 to 90 °C with steam at 3 bar(g), U = 400 W/m²K, A = 12 m².

  1. Steam condenses at about 144 °C.
  2. θ = (5,000 × 3,500 ÷ 4,800) × ln(114 ÷ 54) ≈ 2,730 s ≈ 46 minutes.
  3. Heat duty ≈ 292 kWh, about 490 kg of steam per batch before losses.

Frequently asked questions

What U value should I use for a jacketed reactor?

Roughly 300–600 W/m²K for agitated stainless vessels with steam or water, 200–350 for glass-lined vessels, and higher for internal coils. Viscous batches are lower.

How can I speed up heating?

Increase steam pressure (temperature difference), improve agitation, add a half-pipe jacket or internal coil for more area, and keep the jacket free of air and condensate.

Does this include the vessel's own heat capacity?

No. For heavy vessels, add the steel mass × 0.5 kJ/kg·K to the batch heat capacity.

Need it designed and built?

SEMCO designs, fabricates and commissions evaporators, ZLD plants, heat exchangers, reactors and vacuum systems in its own factories in Pune and Solapur.

Results are engineering estimates for early sizing and budgeting. Final designs depend on your liquid, site and codes, and are confirmed in SEMCO's proposal. Method reviewed by Jogender Dhayal, Director, SEMCO.