Steam & utilities · Free tool
Saturated steam table calculator
Find the temperature, latent heat, enthalpy and specific volume of saturated steam at any pressure, in the units used on Indian plants: bar(g), kg/cm²(g), psi(g) or absolute. It also tells you how much steam a heat duty needs.
Look up saturated steam
Look up by
1.013 at sea level; about 0.95 in Pune.
Steam needed for a heat duty
Condensing steam at this pressure, condensate leaving saturated.
Steam flow: 879 kg/h (4,30,000 kcal/h)
Saturation temperature
170.48°C
Latent heat (hfg)
2,047.3kJ/kg
489.0 kcal/kg
Steam specific volume
0.24m³/kg
| Pressure, absolute | 8.0132 bar(a) = 801.32 kPa(a) |
|---|---|
| Pressure, gauge | 7.000 bar(g) = 7.138 kg/cm²(g) |
| Temperature | 170.48 °C |
| Enthalpy of water (hf) | 721.1 kJ/kg (172.2 kcal/kg) |
| Latent heat (hfg) | 2,047.3 kJ/kg (489.0 kcal/kg) |
| Enthalpy of steam (hg) | 2,768.4 kJ/kg (661.2 kcal/kg) |
| Specific volume of water (vf) | 1.115 L/kg |
| Specific volume of steam (vg) | 0.24 m³/kg |
| Density of water | 897.0 kg/m³ |
| Density of steam | 4.167 kg/m³ |
Want these numbers checked?
Send them to a SEMCO process engineer for a free review, sizing and budget price.
Saturated steam table by gauge pressure
Atmospheric pressure taken as 1.013 bar. kJ/kg ÷ 4.1868 = kcal/kg.
| bar(g) | kg/cm²(g) | Temp °C | hf kJ/kg | hfg kJ/kg | hg kJ/kg | vg m³/kg |
|---|---|---|---|---|---|---|
| 0 | 0.00 | 100.0 | 419.1 | 2,256.7 | 2,675.7 | 1.6734 |
| 0.5 | 0.51 | 111.6 | 468.2 | 2,225.5 | 2,693.7 | 1.1499 |
| 1 | 1.02 | 120.4 | 505.6 | 2,201.2 | 2,706.7 | 0.8803 |
| 1.5 | 1.53 | 127.6 | 536.1 | 2,180.9 | 2,716.9 | 0.7152 |
| 2 | 2.04 | 133.7 | 562.1 | 2,163.2 | 2,725.3 | 0.6033 |
| 2.5 | 2.55 | 139.0 | 584.8 | 2,147.5 | 2,732.3 | 0.5224 |
| 3 | 3.06 | 143.7 | 605.1 | 2,133.2 | 2,738.4 | 0.4610 |
| 3.5 | 3.57 | 148.0 | 623.6 | 2,120.1 | 2,743.6 | 0.4128 |
| 4 | 4.08 | 151.9 | 640.5 | 2,107.9 | 2,748.3 | 0.3739 |
| 4.5 | 4.59 | 155.5 | 656.1 | 2,096.4 | 2,752.5 | 0.3418 |
| 5 | 5.10 | 158.9 | 670.7 | 2,085.6 | 2,756.3 | 0.3149 |
| 6 | 6.12 | 165.0 | 697.3 | 2,065.6 | 2,762.9 | 0.2723 |
| 7 | 7.14 | 170.5 | 721.1 | 2,047.3 | 2,768.4 | 0.2400 |
| 8 | 8.16 | 175.4 | 742.8 | 2,030.3 | 2,773.1 | 0.2146 |
| 9 | 9.18 | 179.9 | 762.7 | 2,014.5 | 2,777.2 | 0.1941 |
| 10 | 10.20 | 184.1 | 781.2 | 1,999.5 | 2,780.7 | 0.1772 |
| 11 | 11.22 | 188.0 | 798.5 | 1,985.3 | 2,783.7 | 0.1631 |
| 12 | 12.24 | 191.7 | 814.7 | 1,971.7 | 2,786.5 | 0.1510 |
| 13 | 13.26 | 195.1 | 830.1 | 1,958.8 | 2,788.8 | 0.1407 |
| 14 | 14.28 | 198.3 | 844.6 | 1,946.3 | 2,790.9 | 0.1316 |
| 15 | 15.30 | 201.4 | 858.5 | 1,934.2 | 2,792.8 | 0.1236 |
| 16 | 16.32 | 204.3 | 871.8 | 1,922.6 | 2,794.4 | 0.1166 |
| 17 | 17.34 | 207.1 | 884.5 | 1,911.3 | 2,795.9 | 0.1103 |
| 18 | 18.35 | 209.8 | 896.8 | 1,900.4 | 2,797.1 | 0.1046 |
| 20 | 20.39 | 214.9 | 919.9 | 1,879.3 | 2,799.2 | 0.0949 |
| 22 | 22.43 | 219.6 | 941.5 | 1,859.2 | 2,800.8 | 0.0868 |
| 25 | 25.49 | 226.1 | 971.7 | 1,830.6 | 2,802.3 | 0.0769 |
| 30 | 30.59 | 235.7 | 1,017.0 | 1,786.1 | 2,803.1 | 0.0645 |
| 35 | 35.69 | 244.2 | 1,057.6 | 1,744.7 | 2,802.3 | 0.0554 |
| 40 | 40.79 | 251.8 | 1,094.6 | 1,705.6 | 2,800.2 | 0.0485 |
Steam under vacuum: evaporator and condenser temperatures
Boiling temperature of water and the matching absolute pressure, as used in vacuum evaporators and condensers.
| Temp °C | mbar(a) | mmHg(a) | Vacuum mmHg | hfg kJ/kg | vg m³/kg |
|---|---|---|---|---|---|
| 40 | 73.9 | 55.4 | 705 | 2,406.1 | 19.515 |
| 45 | 96.0 | 72.0 | 688 | 2,394.1 | 15.251 |
| 50 | 123.5 | 92.7 | 667 | 2,382.0 | 12.026 |
| 55 | 157.6 | 118.2 | 642 | 2,369.9 | 9.564 |
| 60 | 199.5 | 149.6 | 610 | 2,357.7 | 7.667 |
| 65 | 250.4 | 187.8 | 572 | 2,345.4 | 6.193 |
| 70 | 312.0 | 234.0 | 526 | 2,333.1 | 5.040 |
| 75 | 386.0 | 289.5 | 471 | 2,320.7 | 4.129 |
| 80 | 474.2 | 355.6 | 404 | 2,308.1 | 3.405 |
| 85 | 578.7 | 434.0 | 326 | 2,295.4 | 2.826 |
| 90 | 701.8 | 526.4 | 234 | 2,282.6 | 2.359 |
| 95 | 846.1 | 634.6 | 125 | 2,269.7 | 1.981 |
| 100 | 1,014.2 | 760.7 | 0 | 2,256.6 | 1.672 |
How this calculator works
Properties are calculated, not looked up, using the IAPWS auxiliary equations for the saturation line of water (Wagner and Pruss). These give the saturation pressure, and the densities of saturated water and steam, as a function of temperature. Enthalpy of water comes from the IAPWS auxiliary enthalpy equation, and latent heat from the Clapeyron equation, which links latent heat to the slope of the vapour pressure curve.
When you enter a pressure, the calculator finds the matching saturation temperature by repeatedly halving the temperature range until the pressures agree. Results agree with standard steam tables to about 0.1 percent between 0 °C and 350 °C.
Gauge pressure is converted to absolute by adding atmospheric pressure. At sea level that is 1.013 bar; in hill towns it is lower, which slightly lowers the steam temperature for the same gauge reading.
Formulas used
Saturation pressure (Wagner and Pruss)
Tc = 647.096 K, Pc = 22.064 MPa.
Latent heat from the Clapeyron equation
Steam needed for a heat duty
Assumptions and limits
- Saturated conditions only: dry saturated steam and saturated water. Superheated steam is not covered.
- Steam for a heat duty assumes the steam condenses fully and the condensate leaves at saturation temperature, with no subcooling.
- Valid from the triple point (0.01 °C) up to the critical point (373.9 °C, 220.6 bar(a)).
Worked example
A jacketed reactor uses steam at 7 bar(g) to supply 500 kW of heat.
- Absolute pressure = 7 + 1.013 = 8.013 bar(a).
- Saturation temperature at 8.01 bar(a) ≈ 170.4 °C.
- Latent heat at that pressure ≈ 2,048 kJ/kg.
- Steam flow = 500 kW × 3,600 ÷ 2,048 kJ/kg ≈ 879 kg/h.
Frequently asked questions
What is the temperature of steam at 10 bar?
Saturated steam at 10 bar(g), which is about 11 bar(a), is at about 184 °C. At 10 bar(a) it is about 180 °C. Always check whether a pressure is gauge or absolute.
Why does latent heat fall as pressure rises?
As pressure and temperature rise, the liquid and vapour become more alike, so less energy is needed to turn water into steam. Latent heat falls from about 2,257 kJ/kg at atmospheric pressure to zero at the critical point.
Is higher-pressure steam better for heating?
Higher pressure gives a higher temperature and so a bigger driving force, but less latent heat per kilogram. For most process heating, the lowest pressure that gives enough temperature difference is the most efficient.
What is the difference between bar(g) and bar(a)?
Bar(g) is measured above atmospheric pressure, as most plant gauges show. Bar(a) is measured from a perfect vacuum. Bar(a) = bar(g) + atmospheric pressure, about 1.013 bar at sea level.
How do I convert kg/cm² to bar?
1 kg/cm² = 0.980665 bar. So 10 kg/cm²(g) is about 9.81 bar(g).
Need it designed and built?
SEMCO designs, fabricates and commissions evaporators, ZLD plants, heat exchangers, reactors and vacuum systems in its own factories in Pune and Solapur.
Related tools
Heat exchanger LMTD and area calculator
Heat duty, missing outlet temperature, LMTD, F-correction and the heat transfer area you need.
Pipe sizing and pressure drop calculator
Velocity, Reynolds number, friction factor and pressure drop for liquids and steam, with recommended pipe size.
Evaporator energy and cost comparison
Single effect, multi-effect, TVR and MVR side by side: steam, power, annual cost and payback.
Results are engineering estimates for early sizing and budgeting. Final designs depend on your liquid, site and codes, and are confirmed in SEMCO's proposal. Method reviewed by Jogender Dhayal, Director, SEMCO.