Steam & utilities · Free tool
Compressor and blower power calculator
Estimate the power to compress air or a process gas, the discharge temperature and a motor size, for single-stage blowers through multi-stage intercooled compressors.
1. Gas and flow
Air 1.40, N₂ 1.40, CO₂ 1.29, CH₄ 1.31
2. Pressures
3. Machine
Screw 70–80%, centrifugal 75–85%, roots blower 55–70%
Motor input power
128.2kW
Next motor 160 kW (+10%)
Gas (isentropic/η) power
119.2kW
Discharge temperature
366°C
| Overall pressure ratio | 7.897 |
|---|---|
| Pressure ratio per stage | 7.897 |
| Actual inlet flow | 1,128.4 m³/h |
| Specific power | 7.694 kW per Nm³/min |
Want these numbers checked?
Send them to a SEMCO process engineer for a free review, sizing and budget price.
How this calculator works
The calculator uses the isentropic (adiabatic) work of compression divided by an isentropic efficiency. With several stages, the pressure ratio is split equally and the gas is assumed to be cooled back to the inlet temperature between stages, which saves power.
Discharge temperature per stage follows from the isentropic temperature rise divided by efficiency. Motor input adds mechanical and motor losses.
Formulas used
Isentropic power per stage
Discharge temperature
Assumptions and limits
- Ideal gas with constant k; real gases near saturation or at high pressure need polytropic methods and Z.
- Perfect intercooling back to the inlet temperature and no interstage pressure loss.
- Oil-injected screw compressors run cooler than the adiabatic discharge temperature shown because the oil removes heat.
Worked example
1,000 Nm³/h of air from 1.013 to 8 bar(a), inlet 35 °C, one stage, 75% isentropic efficiency.
- Actual inlet flow ≈ 1,128 m³/h; pressure ratio 7.9.
- Isentropic power ÷ 0.75 ≈ 119 kW; with 93% mechanical and motor efficiency, about 128 kW input.
- Two stages with intercooling would cut this by roughly 12–15%.
Frequently asked questions
How much power does an air compressor need per m³/min?
At 7 bar(g), typical packaged screw compressors use about 6–7 kW per m³/min of free air delivered. Lower pressures need less.
Why use multi-stage compression?
Cooling the gas between stages reduces the volume to be compressed, which saves power and keeps discharge temperatures within limits.
What is the difference between a blower and a compressor?
Blowers work at low pressure ratios (up to about 2), compressors at higher ratios. The same equations apply.
Need it designed and built?
SEMCO designs, fabricates and commissions evaporators, ZLD plants, heat exchangers, reactors and vacuum systems in its own factories in Pune and Solapur.
Related tools
Gas flow conversion (Nm³/h, m³/h, kg/h)
Convert between Nm³/h, Sm³/h, actual m³/h at line conditions, kg/h and SCFM.
Vacuum pump-down time calculator
How long a vacuum pump takes to evacuate a vessel, or the pump size you need for a target time.
Pump head, power and NPSH
Total head, shaft power, motor size and NPSH available for a centrifugal pump.
Results are engineering estimates for early sizing and budgeting. Final designs depend on your liquid, site and codes, and are confirmed in SEMCO's proposal. Method reviewed by Jogender Dhayal, Director, SEMCO.