Vacuum pump-down time and pump size calculator

Work out how long a vacuum pump takes to evacuate a reactor, dryer, evaporator or receiver, or what pump capacity you need to reach a vacuum in a given time. The calculation allows for the pump's ultimate pressure.

Pump-down timePump size m³/h

1. What to work out

Mode

2. System

m³

Vessel plus pipework and condenser shell.

mbar(a)
mbar(a)
m³/h

1.2–1.5 covers leaks, outgassing and piping losses.

Pump-down time

7.7min

5.9 min ideal × 1.3

Time constant V/S

2.00min

Pressure ratio

10.1

Time to reach each pressure
200 mbar(a)4.83 min
100 mbar(a)7.69 min

Want these numbers checked?

Send them to a SEMCO process engineer for a free review, sizing and budget price.

Discuss on WhatsApp

How this calculator works

During pump-down, the gas removed each moment is the pump speed times the pressure. Integrating this over time gives a logarithmic decay: each time constant (volume divided by pump speed) reduces the pressure by a factor of about 2.7.

A real pump loses speed as it approaches its ultimate pressure. The calculator models this by reducing the effective speed in proportion to how close the pressure is to that ultimate value, which is why a pump-down slows sharply near the end.

The safety factor covers small leaks, vapour from wet surfaces or product, and the resistance of piping between the vessel and the pump.

Formulas used

Pump-down time with ultimate pressure

t=VSlnP1−PuP2−Pu

Pump speed for a target time

S=VtlnP1−PuP2−Pu

Assumptions and limits

  • Dry gas pump-down. If the vessel holds liquid or wet product, vapour from it can dominate and the pump-down takes much longer; size for the vapour load instead.
  • Pump speed is the nominal suction capacity, assumed constant above the ultimate pressure apart from the approach to ultimate.
  • Piping conductance is not calculated. Short, generously sized suction lines are assumed; the safety factor covers modest losses.
  • Ultimate pressures for each pump type are typical values; check the manufacturer's curve.

Worked example

Evacuate a 10 m³ reactor from 1,013 mbar to 100 mbar with a 300 m³/h liquid ring pump (ultimate about 50 mbar).

  1. Time constant V/S = 10 ÷ 300 h = 2 minutes.
  2. ln((1,013 − 50) ÷ (100 − 50)) = ln(19.3) ≈ 2.96.
  3. Ideal time = 2 × 2.96 ≈ 5.9 minutes.
  4. With a 1.3 safety factor, plan for about 7.7 minutes.

Frequently asked questions

How do I calculate vacuum pump-down time?

Divide the volume by the pump speed to get the time constant, and multiply by the natural log of the start pressure over the end pressure. Subtract the pump's ultimate pressure from both pressures for a more realistic answer.

Why does pump-down slow down near the end?

Because a pump's effective speed drops as it approaches its ultimate pressure, and leaks and outgassing become a larger share of the gas load at low pressure.

Which vacuum pump suits a process reactor?

Liquid ring pumps handle wet, condensable vapours down to about 30 to 50 mbar. Dry screw pumps reach below 1 mbar without seal water and let you recover solvents. For deep vacuum, a Roots booster is added.

Does a bigger pump always help?

Only up to the point where the suction pipe and vapour load limit flow. Beyond that, a larger suction line or a condenser before the pump is often the better fix.

Need it designed and built?

SEMCO designs, fabricates and commissions evaporators, ZLD plants, heat exchangers, reactors and vacuum systems in its own factories in Pune and Solapur.

Results are engineering estimates for early sizing and budgeting. Final designs depend on your liquid, site and codes, and are confirmed in SEMCO's proposal. Method reviewed by Jogender Dhayal, Director, SEMCO.