Vessels & fabrication · Free tool
Pressure vessel shell and head thickness calculator (ASME VIII Div 1)
Calculate the minimum thickness of a cylindrical shell and 2:1 ellipsoidal, torispherical and hemispherical heads under internal pressure, with corrosion allowance, joint efficiency and standard plate selection.
1. Design conditions
Include static head of liquid if significant
Typical CS 1.5–3 mm, SS 0–1 mm
2. Material and welding
Values are ambient-temperature allowables; check ASME II-D at design temperature
3. Geometry
Heads lose 10–15% thickness when formed; add allowance
Shell plate (nominal)
12mm
Required 8.58 mm + allowances
2:1 ellipsoidal head
12mm
Before forming
Hydrotest pressure
13bar(g)
1.3 × design (UG-99), stress ratio 1
| Allowable stress S used | 138 MPa |
|---|---|
| Joint efficiency E | 0.85 |
| MAWP of selected shell plate (corroded) | 11.87 bar(g) |
Required thickness (mm)
| Part | Pressure t | + CA + tolerance | Plate |
|---|---|---|---|
| Cylindrical shell (UG-27) | 8.58 | 10.38 | 12 mm |
| 2:1 ellipsoidal head (UG-32(d)) | 8.55 | 10.35 | 12 mm |
| Torispherical F&D head (UG-32(e)) | 15.13 | 16.93 | 18 mm |
| Hemispherical head (UG-32(f)) | 4.27 | 6.07 | 8 mm |
Want these numbers checked?
Send them to a SEMCO process engineer for a free review, sizing and budget price.
How this calculator works
The shell thickness follows ASME Section VIII Division 1, UG-27: the larger of the circumferential and longitudinal stress requirements. Heads follow UG-32. Dimensions are taken in the corroded condition by adding the corrosion allowance to the radius.
Corrosion allowance and plate under-tolerance (or forming thinning for heads) are then added and the next standard plate thickness selected. The maximum allowable working pressure of the chosen shell plate is shown as a check.
Formulas used
Cylindrical shell (UG-27, circumferential)
2:1 ellipsoidal head (UG-32(d))
Torispherical head (UG-32(e))
Assumptions and limits
- Internal pressure only, thin-wall range (P ≤ 0.385 S E). External pressure and vacuum (UG-28), nozzle reinforcement, supports, wind and seismic loads need separate checks.
- Allowable stresses listed are ambient-temperature values for common plates; use ASME II-D values at your design temperature.
- Torispherical heads assume crown radius = D and knuckle radius = 6% of D.
- Hydrotest at 1.3 × design pressure, assuming equal allowable stress at test and design temperature.
Worked example
2,000 mm ID carbon steel vessel (SA-516 Gr 70, S = 138 MPa) at 10 bar(g), spot radiography (E = 0.85), 1.5 mm corrosion allowance.
- P = 1.0 MPa, corroded R = 1,001.5 mm, S·E = 117.3 MPa.
- t = 1.0 × 1,001.5 ÷ (117.3 − 0.6) ≈ 8.6 mm.
- Add 1.5 mm CA and 0.3 mm tolerance ≈ 10.4 mm, so a 12 mm plate.
- The 12 mm shell's MAWP in the corroded condition is about 11.9 bar(g).
Frequently asked questions
How do I calculate pressure vessel shell thickness?
Under ASME VIII Div 1, t = P R ÷ (S E − 0.6 P), with R the inside radius in the corroded condition, S the allowable stress at design temperature and E the joint efficiency. Then add corrosion allowance.
Which head is thinnest for the same pressure?
A hemispherical head needs about half the shell thickness, a 2:1 ellipsoidal head about the same as the shell, and a torispherical head somewhat more.
What joint efficiency should I use?
1.0 for fully radiographed butt welds, 0.85 for spot radiography and 0.70 with no radiography (Table UW-12, Type 1 joints).
Need it designed and built?
SEMCO designs, fabricates and commissions evaporators, ZLD plants, heat exchangers, reactors and vacuum systems in its own factories in Pune and Solapur.
Related tools
Tank and vessel volume
Total and partly filled volume of vertical or horizontal tanks with dished or conical heads, with a strapping table.
Steel weight calculator
Weight of plates, pipes, shells, bars and rings in CS, SS, duplex, titanium and more.
Safety valve sizing (API 520)
Required relief orifice area and API 526 orifice letter for gas, steam and liquid.
Results are engineering estimates for early sizing and budgeting. Final designs depend on your liquid, site and codes, and are confirmed in SEMCO's proposal. Method reviewed by Jogender Dhayal, Director, SEMCO.