Safety valve sizing calculator (API 520)

Size a pressure safety valve for gas, vapour, steam or liquid relief. Enter the relieving rate and set pressure to get the required orifice area and the API 526 orifice letter.

Area mm²Orifice letter

1. Relieving fluid

Fluid

kg/kmol

Air 28.96, N₂ 28.0, CO₂ 44.0, CH₄ 16.0

–
–

2. Relief conditions

%

10% single valve, 16% multiple valves, 21% fire case

Required orifice area

527.5mm²

0.8176 in²

API 526 orifice

J

Effective area 830.3 mm²

Relieving pressure

11bar(g)

Details
Relieving pressure P112.013 bar(a)
Gas constant C0.02703
Critical flow pressure6.346 bar(a)
Discharge coefficient Kd0.975

API 526 effective orifice areas

LetterArea mm²Area in²
D710.11
E126.50.196
F198.10.307
G324.50.503
H506.50.785
J830.31.287
K1,185.81.838
L1,840.62.853
M2,322.63.6
N2,8004.34
P4,1166.38
Q7,12911.05
R10,32316.001
T16,77426

Want these numbers checked?

Send them to a SEMCO process engineer for a free review, sizing and budget price.

Discuss on WhatsApp

How this calculator works

The relieving pressure is the set pressure plus the allowable overpressure (10% for a single valve in most cases), converted to absolute pressure.

Gas and vapour relief uses the API 520 Part I critical flow equation with the coefficient C from the specific heat ratio. Steam uses the Napier equation, with the KN correction above about 103 bar(a). Liquid relief uses the API 520 equation for certified liquid-trim valves.

The required area is then matched to the next standard API 526 orifice (D to T).

Formulas used

Gas or vapour (critical flow)

A=WC Kd P1 Kb Kc√TZM

A in mm², W in kg/h, P1 in kPa(a), T in K. C = 0.03948 √(k (2/(k+1))^((k+1)/(k−1))).

Saturated steam (Napier)

A=190.5 WP1KdKbKcKNKSH

Liquid

A=11.78 QKdKwKcKv√GP1−P2

Q in L/min, pressures in kPa.

Assumptions and limits

  • Kd = 0.975 for gas and steam, 0.65 for liquid; Kb, Kc, Kw and Kv = 1 (conventional valve, no rupture disc, low viscosity).
  • Gas flow is critical (back pressure below the critical flow pressure); a warning appears if it is not.
  • The relieving rate must come from your overpressure scenario analysis (blocked outlet, fire, control valve failure and so on).
  • Inlet and outlet piping pressure losses (3% inlet rule, built-up back pressure) are not checked.

Worked example

5,000 kg/h of air at 50 °C, set pressure 10 bar(g), 10% overpressure.

  1. P1 = 10 × 1.1 + 1.013 = 12.01 bar(a) = 1,201 kPa(a).
  2. For k = 1.4, C = 0.02703.
  3. A = 5,000 ÷ (0.02703 × 0.975 × 1,201) × √(323 × 1 ÷ 28.96) ≈ 528 mm².
  4. The next API 526 orifice is J (830 mm²), since H (506 mm²) is too small.

Frequently asked questions

What is API 520?

The American Petroleum Institute's standard for sizing, selecting and installing pressure-relieving devices. Part I covers sizing; API 526 lists standard orifice areas.

What overpressure should I use?

Typically 10% for a single valve, 16% when several valves protect the same vessel, and 21% for fire cases, within the code's limits.

Can I size a valve for two-phase relief with this tool?

No. Two-phase relief, such as runaway reactions or flashing liquids, needs methods like API 520 Annex C or DIERS.

Need it designed and built?

SEMCO designs, fabricates and commissions evaporators, ZLD plants, heat exchangers, reactors and vacuum systems in its own factories in Pune and Solapur.

Results are engineering estimates for early sizing and budgeting. Final designs depend on your liquid, site and codes, and are confirmed in SEMCO's proposal. Method reviewed by Jogender Dhayal, Director, SEMCO.