Control valve Cv and Kv sizing calculator

Size a control valve for liquid, gas or steam service. The calculator gives the required Kv and Cv, checks for choked flow and cavitation, and suggests a typical globe valve size.

KvCvChoked flowValve size

1. Service

Fluid

2. Flow and conditions

–
–

Globe 0.85–0.9, ball 0.6, butterfly 0.55–0.7

Required Kv

21.21m³/h

Required Cv

24.52US

Typical globe valve

2"

Full-open Cv about 50

Details
Pressure drop2 bar
Choked-flow limit ΔP5.657 bar
Cv = 1.156 × Kv24.52
Cv to select (+25% so the valve runs about 70–80% open)30.7

Want these numbers checked?

Send them to a SEMCO process engineer for a free review, sizing and budget price.

Discuss on WhatsApp

How this calculator works

Kv is the flow of water in m³/h through a valve with a 1 bar pressure drop; Cv is the US equivalent in gallons per minute at 1 psi. Cv = 1.156 × Kv.

For liquids, Kv follows from flow, specific gravity and pressure drop. If the pressure drop exceeds the choked limit set by the valve's recovery factor FL and the liquid's vapour pressure, the choked value is used and a cavitation warning is shown.

For gas and steam the standard (Samson/IEC-style) formulas are used, with separate subcritical and critical (sonic) forms. Critical flow starts when the pressure drop reaches about half the inlet absolute pressure.

A valve is normally selected with about 25% more Cv than required, so it controls at roughly 70–80% open.

Formulas used

Liquid

Kv=Q√SGΔP, ΔPchoked=F2L(P1−FFPv)

Gas, subcritical

Kv=QN514√ρNT1ΔP P2

Critical: Kv = QN ÷ (257 P1) × √(ρN T1). Pressures in bar(a), T in K.

Steam, subcritical

Kv=W31.62√v2ΔP

W in kg/h, v₂ the specific volume in m³/kg.

Assumptions and limits

  • Turbulent, non-viscous flow; viscous liquids need a Reynolds-number correction.
  • Piping geometry factor Fp = 1 (valve the same size as the line).
  • Steam is dry saturated.
  • Valve Cv values shown are typical for single-seat globe valves; use the manufacturer's tables for the final selection.

Worked example

30 m³/h of water, 6 bar(g) in and 4 bar(g) out, globe valve FL = 0.9.

  1. ΔP = 2 bar, well below the choked limit of about 5.7 bar.
  2. Kv = 30 × √(1/2) ≈ 21.2 m³/h; Cv ≈ 24.5.
  3. With 25% margin, select a valve with Cv ≈ 31: typically a 2" globe valve with reduced trim, or a 1½" full-trim valve.

Frequently asked questions

What is the difference between Cv and Kv?

Both measure valve capacity. Kv is in m³/h of water at 1 bar drop; Cv is in US gpm at 1 psi drop. Cv = 1.156 × Kv.

Why should a control valve not be oversized?

An oversized valve works near its seat, where small movements cause big flow changes, so control becomes unstable and the trim wears faster.

What is choked flow in a valve?

For liquids, it is when the pressure in the valve's throat falls to the vapour pressure and vapour forms; further pressure drop no longer increases flow and cavitation damage can start. For gases, it is sonic velocity in the throat.