Pumps, piping & valves · Free tool
Orifice plate flow calculator
Calculate the flow through an orifice plate from its differential pressure, or size a restriction orifice bore for a given flow. Works for liquids and gases.
1. What to work out
Calculate
2. Pipe and orifice
Sharp-edged orifice about 0.60–0.62
3. Fluid
Fluid
Mass flow
46,711.4kg/h
46.805 m³/h at line density
Beta ratio d/D
0.587
Permanent pressure loss
0.1593bar
Approx. ΔP × (1 − β¹·⁹)
| Orifice bore | 60 mm |
|---|---|
| Expansibility factor ε | 1 |
| Velocity in the bore | 4.6 m/s |
Want these numbers checked?
Send them to a SEMCO process engineer for a free review, sizing and budget price.
How this calculator works
An orifice converts pressure into velocity at its bore. The mass flow is the discharge coefficient × expansibility × bore area × √(2ΔPρ ÷ (1 − β⁴)), where β is bore diameter ÷ pipe diameter.
For gases, the ISO 5167-2 expansibility factor ε corrects for the gas expanding through the bore. To size a bore, the calculator searches for the diameter that passes your target flow at the given ΔP.
Formulas used
Orifice flow
Expansibility (ISO 5167-2)
Assumptions and limits
- Sharp-edged concentric orifice with a constant discharge coefficient (0.61 by default). Precise metering needs the Reader-Harris/Gallagher Cd for your tappings and Reynolds number.
- Single-stage orifice; large gas pressure drops need multi-stage plates to avoid choking and noise.
- Permanent pressure loss is approximated as ΔP × (1 − β¹·⁹).
Worked example
Water in a 100 NB Sch 40 pipe (102.3 mm bore) with a 60 mm orifice and 0.25 bar differential.
- β = 60 ÷ 102.3 = 0.587, so 1 − β⁴ = 0.881.
- Velocity in the bore = 0.61 ÷ √0.881 × √(2 × 25,000 ÷ 998) ≈ 4.6 m/s.
- Mass flow ≈ 4.6 × 0.002827 m² × 998 × 3,600 ≈ 46,700 kg/h.
Frequently asked questions
What beta ratio should an orifice plate have?
Usually between 0.2 and 0.75. Low β gives a high pressure loss; high β gives a small, less accurate differential.
What is a restriction orifice?
A plate used to limit flow or drop pressure rather than measure it, for example on a bypass, a purge line or a pump minimum-flow line.
How much pressure does an orifice plate permanently lose?
Roughly 40–75% of the measured differential, depending on β; the rest is recovered downstream.
Need it designed and built?
SEMCO designs, fabricates and commissions evaporators, ZLD plants, heat exchangers, reactors and vacuum systems in its own factories in Pune and Solapur.
Read more
Related tools
Control valve Cv and Kv sizing
Required Kv and Cv for liquid, gas and steam, with choked-flow check and a typical valve size.
Gas flow conversion (Nm³/h, m³/h, kg/h)
Convert between Nm³/h, Sm³/h, actual m³/h at line conditions, kg/h and SCFM.
Pipe sizing and pressure drop calculator
Velocity, Reynolds number, friction factor and pressure drop for liquids and steam, with recommended pipe size.
Results are engineering estimates for early sizing and budgeting. Final designs depend on your liquid, site and codes, and are confirmed in SEMCO's proposal. Method reviewed by Jogender Dhayal, Director, SEMCO.