SEMCO
Get a Quote

Separation & distillation · Free tool

Particle settling velocity calculator

Calculate how fast a particle settles (or rises) in a liquid or gas, across the Stokes, intermediate and Newton regimes. Useful for clarifiers, settling tanks, crystallisers and cyclone checks.

mm/sReOverflow rate

1. Particle

µm
kg/m³

Sand 2,650, salt crystals 2,160, CaCO₃ 2,710

2. Fluid

kg/m³
cP

Settling velocity

7.977mm/s

28.72 m/h

Particle Reynolds number

0.796

Stokes (laminar)

Drag coefficient

34

Details
Stokes' law velocity9 mm/s
Max surface overflow rate to capture this size28.72 m³/m²·h
Time to settle 1 m2.089 min
Single smooth sphere in still fluid. Crowded slurries settle slower (hindered settling) and irregular particles have higher drag.

Want these numbers checked?

Send them to a SEMCO process engineer for a free review, sizing and budget price.

Discuss on WhatsApp

How this calculator works

A particle reaches terminal velocity when drag balances its weight minus buoyancy. Drag depends on the particle Reynolds number, so the calculator iterates between velocity and drag coefficient.

It uses the Schiller-Naumann drag correlation up to Re 1,000 and Newton's constant drag coefficient of 0.44 above that. At low Reynolds numbers this reduces to Stokes' law.

Formulas used

Terminal velocity

vt=√4gd(ρp−ρf)3CDρf

Stokes' law (Re < 1)

vt=gd2(ρp−ρf)18μ

Assumptions and limits

  • Single, smooth, spherical particle in a still, unbounded fluid.
  • Hindered settling in concentrated slurries makes real velocities lower.
  • The surface overflow rate shown is the clarifier loading that would just capture this particle size.

Worked example

A 100 µm sand particle (2,650 kg/m³) in water at 20 °C.

  1. Stokes' law gives about 9.0 mm/s, but Re ≈ 0.8, close to the limit of the laminar range.
  2. With the Schiller-Naumann correction the velocity is about 8.0 mm/s (28.7 m/h).

Frequently asked questions

When does Stokes' law apply?

For particle Reynolds numbers below about 1, typically fine particles under about 100 µm in water.

How is settling velocity used to size a clarifier?

A clarifier captures particles whose settling velocity exceeds its surface overflow rate (flow ÷ surface area).

Why do crystals settle slower in my crystalliser than calculated?

High solids concentration (hindered settling), upward liquid flow and irregular crystal shapes all reduce the effective settling velocity.

Need it designed and built?

SEMCO designs, fabricates and commissions evaporators, ZLD plants, heat exchangers, reactors and vacuum systems in its own factories in Pune and Solapur.

Results are engineering estimates for early sizing and budgeting. Final designs depend on your liquid, site and codes, and are confirmed in SEMCO's proposal. Method reviewed by Jogender Dhayal, Director, SEMCO.