Vapour-liquid separator and knockout drum sizing
Size a vertical vapour-liquid separator, knockout drum or evaporator vapour body. The calculator finds the diameter that keeps droplets out of the vapour, and a height that gives enough liquid hold-up and disengagement space.
1. Vapour
Vapour
Vapour density 0.13 kg/m³
2. Liquid
2–5 min for level control; more for pump protection.
Foaming liquid?
3. Design
Vessel diameter
1,200mm
Straight height
2.55m
H/D = 2.1
Vapour velocity
5.65m/s
max 7.68 m/s
| Vapour volume flow | 23,001 m³/h |
|---|---|
| K used (after derating) | 0.086 m/s |
| Minimum area | 1.040 m² |
| Liquid section | 0.30 m for 3 min hold-up |
| Inlet zone | 0.60 m |
| Disengagement space | 1.20 m |
| Mist eliminator zone | 0.45 m |
| Vapour inlet nozzle (approx.) | 521 mm bore |
Want these numbers checked?
Send them to a SEMCO process engineer for a free review, sizing and budget price.
How this calculator works
Droplets fall out of a rising vapour only if the vapour moves slower than they settle. The Souders-Brown equation sets the maximum vapour velocity from the liquid and vapour densities and a coefficient K that depends on the separator internals: higher for a mesh pad or vane pack, lower for an empty vessel.
For water vapour, the density is taken from the steam table at the boiling temperature. Under vacuum, and for foaming liquids, K is reduced, following common design practice. The diameter is rounded up to the next 50 mm.
Height is built up from the liquid section (set by hold-up time), an inlet zone, a disengagement space of at least 0.9 m or one diameter, and space for the mist eliminator.
Formulas used
Souders-Brown maximum velocity
Vessel diameter
Liquid height
Assumptions and limits
- Vertical vessel with the vapour leaving at the top. Horizontal separators are sized differently.
- K values: mesh pad 0.107 m/s, vane pack 0.15 m/s, empty vessel 0.045 m/s. Reduced 20 percent for vacuum water vapour and 40 percent for foaming liquids.
- Heights use rules of thumb: inlet zone 0.6 m, disengagement at least 0.9 m or one diameter, 0.45 m for a demister.
- Inlet nozzle size is an estimate based on limiting the inlet momentum (ρv²).
Worked example
An evaporator body boiling at 60 °C produces 3,000 kg/h of vapour and 5,000 kg/h of liquid at 1,050 kg/m³, with a mesh pad.
- Water vapour density at 60 °C ≈ 0.13 kg/m³, so the vapour volume is about 23,000 m³/h.
- K = 0.107 × 0.8 (vacuum) ≈ 0.086 m/s. v max = 0.086 × √((1,050 − 0.13) ÷ 0.13) ≈ 7.7 m/s.
- At 80 percent of maximum, the design velocity is about 6.1 m/s and the area needed is about 1.04 m².
- Diameter ≈ 1.15 m, rounded up to the next 50 mm: 1,200 mm.
Frequently asked questions
What K value should I use in the Souders-Brown equation?
About 0.1 m/s with a wire mesh demister, up to 0.15 m/s with a vane pack, and 0.04 to 0.05 m/s for an empty vessel. Reduce it for vacuum service, foaming liquids and high liquid loads.
Why are vacuum separators so large?
Vapour density under vacuum is very low, so the same mass of vapour takes up a much larger volume. A separator at 60 °C handles about four to five times the vapour volume of one boiling at 100 °C for the same flow.
What causes carryover from an evaporator separator?
Vapour velocity above the design limit, foaming, a high liquid level, a damaged or fouled demister, or sudden pressure drops that cause flashing. Carryover contaminates the condensate.
Do I need a demister?
If the vapour is condensed and reused, or goes to a compressor or vacuum pump, a mesh or vane demister is normally worth its small cost because it allows a smaller vessel and cleaner condensate.
Need it designed and built?
SEMCO designs, fabricates and commissions evaporators, ZLD plants, heat exchangers, reactors and vacuum systems in its own factories in Pune and Solapur.
Related tools
Evaporator energy and cost comparison
Single effect, multi-effect, TVR and MVR side by side: steam, power, annual cost and payback.
Saturated steam table calculator
Temperature, pressure, enthalpy, latent heat and specific volume of saturated steam, in bar(g), bar(a), kg/cm² or psi.
Pipe sizing and pressure drop calculator
Velocity, Reynolds number, friction factor and pressure drop for liquids and steam, with recommended pipe size.
Results are engineering estimates for early sizing and budgeting. Final designs depend on your liquid, site and codes, and are confirmed in SEMCO's proposal. Method reviewed by Jogender Dhayal, Director, SEMCO.