SEMCO
Get a Quote

Agitators & mixing · Free tool

Agitator design and comparison tool for reactors and tanks

Enter your reactor and liquid, choose what the agitator must do, and pick up to four impeller types. The tool sets standard proportions and the speed the duty needs, then calculates power, motor, torque, shaft, blend time, solids suspension, gas handling and heat transfer for each, so you can choose with the numbers side by side.

Impeller sizesrpmkW and motorBlend timeSide-by-side
Try an example:

1. Reactor or tank

mm
m³ (KL)

Baffles

Liquid height H1,704 mmH / T0.85

2. Liquid

kg/m³

Use the slurry density if solids are present.

cP (mPa·s)

Water 1 · oils 50–500 · resins 1,000–100,000+

W/m·K
kJ/kg·K

Conductivity and specific heat are used only for the jacket-side film coefficient.

3. Mixing duty

s

Motor speed

Auto speed gives agitation scale 3 (bulk velocity 0.09 m/s) or your blend-time target, whichever needs more speed.

4. Agitator options to compare

Pick an impeller type: the tool fills in its standard proportions and speed. Edit any number to try your own design.

Option 1

Axial flow · 4 blades · General-purpose blending and solids suspension; good all-rounder.

Standard
mm
Standard
mm
Standard
mm
Standard
nos
Auto
rpm

Shaft

0.157 kW

Motor

0.37 kW

Meets the duty

Option 2

Recommended

Axial flow · 3 blades · Most flow per kW; best for blending and solids suspension in low-viscosity liquids.

Standard
mm
Standard
mm
Standard
mm
Standard
nos
Auto
rpm

Shaft

0.104 kW

Motor

0.37 kW

Meets the duty

Option 3

Radial flow · 6 blades · High shear and gas dispersion; high power for the flow it gives.

Standard
mm
Standard
mm
Standard
mm
Standard
nos
Auto
rpm

Shaft

1.76 kW

Motor

3 kW

Meets the duty

Best fit of your options

Hydrofoil (high-efficiency, 3 blades): 1 × 800 mm at 60 rpm, 0.37 kW motor

Meets the blending / homogenising duty with the smallest drive and fewest warnings. Shaft power 0.104 kW, torque 17 N·m, 0.02 kW/m³.

5. Side-by-side comparison

Green marks the best value in a row among the options that meet the duty.

ParameterOption 1Pitched blade turbineOption 2HydrofoilOption 3Rushton disc turbine
Meets the duty?YesYesBestYes
Geometry
Impeller diameter D (mm)800800660
D / T0.400.400.33
Blade width W (mm)160120132
Bottom clearance C (mm)500500660
Impellers on shaft111
Speed and flow
Speed (rpm)43auto60auto83auto
Tip speed (m/s)1.792.522.88
Reynolds number23,879Turbulent33,686Turbulent31,758Turbulent
Power number Np1.270.305.00
Pumping flow (m³/h)1,0351,0351,035
Batch turnovers (per min)3.43.43.4
Agitation scale (1–10)3.03.03.0
Blend time (95%) (s)424820
Power and drive
Shaft power (kW)0.1570.1041.76
Power per volume (kW/m³)0.03140.02090.352
Motor (standard) (kW)0.370.373
Shaft torque (N·m)3517202
Shaft diameter (approx.) (mm)302545
Gearbox ratio (: 1)33.823.917.3
Duty checks
Wall film coefficient h (W/m²·K)6747191,137

6. Arrangement sketch

Option 2: Hydrofoil (high-efficiency, 3 blades). Drawn to scale from your inputs.

T = 2,000 mmH 1,704D 800C 50060 rpm · 0.37 kW

Speed

60rpm

Auto for the duty

Shaft power

0.104kW

0.0209 kW/m³

Motor

0.37kW

Gearbox about 23.9 : 1

Torque

17N·m

Shaft about 25 mm

Tip speed

2.52m/s

Re 33,686, turbulent

Blend time

48s

3.4 turnovers/min

This option meets the duty you selected.

Drive and mechanical notes

Motor sized on the shaft power with 94% gearbox efficiency and a 20% margin. The shaft diameter is a first check at 40 MPa allowable shear with a factor of 2 for bending; final shaft size depends on the overhang, critical speed and the steady bearing, which SEMCO checks during detailed design.

Standard proportions used for this impeller

D/T 0.4, W/D 0.15, C/T 0.25, turbulent power number 0.3, laminar constant Kp 40, pumping number 0.56, Zwietering S 6.2. Gas handling: poor.

Want SEMCO to check this agitator?

Send your reactor data and the options you compared. A SEMCO engineer will confirm the design, the drive and the shaft, and send a budget price.

Discuss on WhatsApp

How this calculator works

1. Vessel and liquid level. From the vessel diameter, bottom head and working volume, the tool solves for the liquid height H. The H/T ratio sets how many impellers go on the shaft: one up to about 1.25, two up to 1.9, three up to 2.6. Anchors and ribbons are always single.

2. Standard geometry. Each impeller type carries its usual proportions: diameter as a fraction of the vessel (D/T), blade width (W/D) and bottom clearance (C/T), along with its power number, laminar constant, pumping number, Zwietering constant and heat-transfer constant. These fill in automatically, and every dimension can be overwritten.

3. Speed for the duty. Unless you enter a speed, the tool finds the speed that meets your duty: an agitation scale of 3 or your blend-time target for blending, scale 5 for heat transfer, 15% above Njs for solids, 2 kW/m³ for gas dispersion, 1 kW/m³ for liquid-liquid dispersion, and a set tip speed for viscous mixing.

4. Detailed results. At that speed it calculates Reynolds number, power number (laminar plus turbulent, with an unbaffled correction), shaft power for all impellers, P/V, torque, tip speed, pumping flow, turnovers, bulk velocity and agitation scale, Grenville blend time, Zwietering Njs, gassed power and flooding, the wall film coefficient, motor size, gearbox ratio and a first shaft size.

5. Comparison and recommendation. Each option is checked against the duty: Reynolds number range, blend time, solids, gas flooding and power level. Among the options that pass, the tool recommends the one with the smallest motor, with a penalty for warnings such as high tip speed.

Formulas used

Reynolds number and power number

Re=ρND2μ, Np=fb Np,turb+KpRe

fb = 1 with baffles; about 0.25 to 0.6 unbaffled depending on impeller.

Shaft power and torque

P=nimp Np ρ N3D5, τ=P2πN

Pumping flow and agitation scale

Q=NqND3, vb=QπT2/4, scale=vb [ft/min]6

Blend time, turbulent (Grenville)

θ95=5.2N1/3pN(TD)2

Transitional: θ95 = 183 ÷ (Np^2/3 N Re) × (T/D)². Close-clearance impellers use N·θ95 ≈ 150 (anchor) and 35 (helical ribbon).

Just-suspended speed (Zwietering)

Njs=S ν0.1(g ΔρρL)0.45X0.13d0.2pD−0.85

Gassed power and flooding

FlG=QgND3, PgP=1−12.6 FlG (FlG<0.035), Flflood=30 Fr(DT)3.5

Wall film coefficient (jacket side of the batch)

h Tk=a Re2/3Pr1/3

a ≈ 0.74 Rushton, 0.53 pitched blade, 0.45 hydrofoil, 0.36 paddle; anchors use 1.0 Re^0.5 in laminar flow.

Motor and shaft

Pmotor=1.2 P0.94, dshaft=(32 τπ τallow)1/3

τallow = 40 MPa; the factor 2 in 32 (instead of 16) allows for bending. Rounded up to standard sizes.

Assumptions and limits

  • Vertical cylindrical vessel with a centre-mounted shaft and standard impeller proportions; the impeller constants are typical published values and vary by maker.
  • Baffled means four baffles of T/12 width. Unbaffled vessels draw less power and the tool warns about vortexing in thin liquids.
  • Multiple impellers are spaced about 1.5 D apart and each draws full power. Closer spacing reduces power per impeller.
  • Blend time from Grenville's correlation is for H = T; a (H/T)^0.5 allowance is added for taller batches. Multi-impeller and close-clearance blend times are rough.
  • Newtonian liquids. For shear-thinning slurries, resins and polymer solutions, use the apparent viscosity at the impeller shear rate, and have the design checked.
  • Shaft size is a first torsion-plus-bending check only. Critical speed, overhang, steady bearings and mechanical seal sizing are done in SEMCO's detailed design.

Worked example

A 2.0 m diameter reactor with a torispherical bottom, 5 m³ of liquid at 1,050 kg/m³ and 20 cP, blending to 95% uniformity in 60 s.

  1. Liquid height is about 1.70 m, so H/T ≈ 0.85 and one impeller is enough.
  2. Pitched blade turbine: standard D = 0.4 × 2.0 = 800 mm. For agitation scale 3 it needs about 43 rpm; Re ≈ 24,000 (turbulent), shaft power ≈ 0.16 kW and blend time ≈ 42 s, inside the 60 s target.
  3. Hydrofoil: same 800 mm diameter but runs at about 60 rpm for the same bulk motion. Power drops to about 0.10 kW because its power number is only 0.3, and blend time is about 48 s.
  4. Rushton turbine: 660 mm at about 83 rpm draws about 1.8 kW for the same bulk motion, more than fifteen times the hydrofoil, and needs a 3 kW motor instead of 0.37 kW, because radial turbines spend power on shear rather than flow.
  5. The tool recommends the hydrofoil. If the batch later needs gas sparging, switch the duty to gas dispersion and the Rushton becomes the recommendation.

Frequently asked questions

How do I choose the right agitator for a reactor?

Start from the duty and the viscosity. For thin liquids, axial hydrofoils and pitched blade turbines give the most flow per kW for blending and solids. Rushton or concave-blade turbines handle gas. Above roughly 5,000 to 10,000 cP, turbines stop mixing the whole batch and anchors or helical ribbons are needed. Compare the options on motor size, torque and whether each one meets the duty.

What are the standard dimensions of an agitator?

Typical proportions are an impeller diameter of 0.3 to 0.5 times the vessel diameter for turbines and hydrofoils (0.95 for anchors), a bottom clearance of about one-quarter to one-third of the vessel diameter, and four baffles of one-twelfth of the vessel diameter. Blade width is about 0.2 times the impeller diameter for turbines.

What is agitation scale or agitation intensity?

It is a 1 to 10 scale based on the bulk liquid velocity, introduced by Chemineer. Scale 1 to 2 suits gentle blending, 3 to 6 is typical for most process reactors, and 7 to 10 is for demanding duties. Each unit equals 6 ft/min (about 0.03 m/s) of bulk velocity.

How many impellers does a tall reactor need?

As a rule of thumb, one impeller for liquid height up to about 1.2 times the vessel diameter, two up to about 1.8, and three up to about 2.5. The tool sets this automatically and you can override it.

Why is my Rushton turbine using so much power?

A Rushton turbine has a power number of about 5, against 1.3 for a pitched blade and 0.3 for a hydrofoil. It converts much of that power into shear, which is useful for gas dispersion but wasteful for plain blending or solids suspension.

Can I trust these numbers for ordering a motor?

They are reliable for comparing options and budgeting. Before ordering, the vendor should confirm the power curve of the exact impeller, the shaft and seal design and any start-up or solids-settled torque. SEMCO does this free for enquiries sent from the tool.

Need it designed and built?

SEMCO designs, fabricates and commissions evaporators, ZLD plants, heat exchangers, reactors and vacuum systems in its own factories in Pune and Solapur.

Results are engineering estimates for early sizing and budgeting. Final designs depend on your liquid, site and codes, and are confirmed in SEMCO's proposal. Method reviewed by Jogender Dhayal, Director, SEMCO.