Agitators & mixing · Free tool
Solids suspension calculator (Zwietering just-suspended speed)
Find the agitator speed that just lifts all solids off the bottom of a tank, and the power and motor needed for each level of suspension. For slurry tanks, dissolvers, catalyst reactors and crystallisers.
1. Impeller and vessel
Standard: 0.4 T for pitched blade and hydrofoil, 0.33 T for Rushton.
2. Solids and liquid
Sand 2,650 · salt 2,160 · catalyst 1,500–3,500 · CaCO₃ 2,710
Just-suspended speed Njs
88rpm
Tip speed 4.41 m/s
Design speed (1.15 Njs)
101rpm
5.42 kW at the shaft
Motor
7.5kW
0.542 kW/m³
| Impeller | Pitched blade turbine (45°, 4 blades) |
|---|---|
| Zwietering S used | 5.6 |
| D/T | 0.4 |
| Solids loading X (kg solids per 100 kg liquid) | 17.6 |
| Slurry density | 1,103 kg/m³ |
| Particle free-settling velocity (Newton estimate) | 121 mm/s |
Speed and power for each suspension level
| Level | rpm | kW | kW/m³ | Tip m/s |
|---|---|---|---|---|
| On-bottom motion (solids moving, some resting) | 61 | 1.22 | 0.122 | 3.09 |
| Just suspended, Njs (no solids rest > 1–2 s) | 88 | 3.57 | 0.357 | 4.41 |
| Design point (15% margin) | 101 | 5.42 | 0.542 | 5.07 |
| Good suspension, cloud height ~ 0.9 H | 132 | 12 | 1.2 | 6.61 |
| Near-uniform suspension | 175 | 28.5 | 2.85 | 8.82 |
Want these numbers checked?
Send them to a SEMCO process engineer for a free review, sizing and budget price.
How this calculator works
Zwietering measured the speed at which no particle rests on the vessel bottom for more than one to two seconds, and fitted it to the liquid viscosity, the density difference, the solids loading, the particle size and the impeller diameter. That speed, Njs, is still the industry's starting point for solids suspension.
The constant S depends on the impeller type and its position in the tank. The tool uses typical values for standard geometry (D/T about 0.33 to 0.4, clearance about T/4); choose 'Other' to enter a value from an impeller maker.
Power at each speed uses the impeller's power number and the slurry density. The table shows the speed and power for on-bottom motion, just suspended, a 15% design margin, good suspension and near-uniform suspension, so you can see how fast power climbs above Njs.
Formulas used
Zwietering just-suspended speed
N in rev/s, ν in m²/s, dp and D in m, X = kg solids per 100 kg liquid.
Shaft power
Assumptions and limits
- Newtonian liquid, fully baffled flat or dished-bottom vessel, single impeller.
- S values are typical for standard geometry; real values vary by ±20% with clearance, blade angle and bottom shape.
- d50 is used as the particle size; a wide size range with a large top size needs a higher speed.
- Above about 40 wt% solids the slurry is non-Newtonian and the correlation is not reliable.
Worked example
300 µm sand at 15 wt% in water, 2.4 m tank, 0.96 m pitched blade turbine.
- X = 15 ÷ 85 × 100 = 17.6. ν = 1 × 10⁻⁶ m²/s, Δρ/ρL = 1.65.
- Njs = 5.6 × (10⁻⁶)^0.1 × (9.81 × 1.65)^0.45 × 17.6^0.13 × (300 × 10⁻⁶)^0.2 × 0.96^-0.85 ≈ 1.46 rev/s, about 88 rpm.
- Design at 1.15 Njs ≈ 101 rpm. With Np 1.27 and a slurry density of about 1,100 kg/m³, the shaft power is about 5.4 kW, or roughly 0.54 kW/m³ in 10 m³.
- With gearbox losses and a 20% margin, specify a 7.5 kW motor. A hydrofoil in the same tank needs about a third of this power.
Frequently asked questions
What is the just-suspended speed Njs?
It is the lowest agitator speed at which no particle stays on the vessel bottom for more than one or two seconds. All solid surface area is then available for reaction or dissolution.
Do I need uniform suspension?
Usually not. Reactions and dissolution need only Njs. Uniform suspension is needed when slurry is drawn off at a fixed level, for example to feed a pump or filter, and it can take two to three times the power.
Which impeller suspends solids with the least power?
Axial-flow impellers pumping down, such as hydrofoils and pitched blade turbines, at about T/4 off the bottom. Radial turbines need noticeably more power for the same duty.
Does particle size matter much?
Less than you might think: Njs rises only with the particle size to the power 0.2. Density difference and solids loading matter more.
Need it designed and built?
SEMCO designs, fabricates and commissions evaporators, ZLD plants, heat exchangers, reactors and vacuum systems in its own factories in Pune and Solapur.
Related tools
Agitator design and comparison tool
Enter your reactor and liquid, pick impellers: get standard dimensions, speed, power, motor, torque, blend time, Njs and h, and compare up to four designs.
Particle settling velocity
Terminal settling velocity from Stokes to Newton regimes, for clarifiers and crystallisers.
Agitator scale-up calculator
Scale a pilot or lab agitator to plant size by constant P/V, tip speed, Njs, blend time or Reynolds number.
Results are engineering estimates for early sizing and budgeting. Final designs depend on your liquid, site and codes, and are confirmed in SEMCO's proposal. Method reviewed by Jogender Dhayal, Director, SEMCO.