SEMCO
Get a Quote
Back to all articles
Process Engineering

CCTS Emission Targets: Cutting Steam Use in Evaporators and Columns

7 min readSEMCO Process Engineering TeamReviewed by Jogender Dhayal

In short

Under India's Carbon Credit Trading Scheme, obligated plants in sectors including textiles, refineries, petrochemicals, chlor-alkali, pulp and paper, cement and aluminium must cut greenhouse-gas emissions per tonne of product. In chemical and textile plants, process steam from coal or fuel-oil boilers is often the largest share. Raising evaporator steam economy, moving to MVR, recovering condensate and flash steam, and heat-integrating columns are usually the fastest, lowest-risk reductions.

India's Carbon Credit Trading Scheme (CCTS) has moved from policy to plant level. In January 2026 the government notified greenhouse-gas emission intensity (GEI) targets for 208 more obligated entities in petroleum refining, petrochemicals, textiles and secondary aluminium. That came on top of the October 2025 targets for aluminium, cement, chlor-alkali and pulp and paper, bringing the total to 490 entities (PIB, 22 January 2026). The targets apply to 2025–26 and 2026–27 against a 2023–24 baseline (CCarbon summary). Plants that beat their targets earn Carbon Credit Certificates they can sell; plants that miss them must make up the gap.

For a textile processing house, a petrochemical unit or a chlor-alkali plant, the question is practical: where do the tonnes of CO2 come from, and which ones can be removed quickly? In most process plants, a large share comes from steam raised in coal, lignite, pet coke or fuel-oil boilers. Steam feeds evaporators, distillation reboilers, dryers and heating jackets. Cutting steam per tonne of product is often the fastest, lowest-risk route to a lower emission intensity.

This article shows how to convert steam to CO2, which equipment uses most of it, and what each improvement typically delivers. It is engineering guidance, not legal advice: confirm the exact rules for your sector with the BEE notification and your accredited verifier.

What does CCTS measure?

Each obligated entity has a baseline output and baseline emission intensity, in tonnes of CO2-equivalent per tonne of product, and a target for each compliance year. Intensity is:

GEI=Total counted GHG emissions (tCO2e)Equivalent product output (t)

Two things follow for engineers:

  • Intensity, not total. You can increase production and still comply, as long as emissions per tonne fall. Debottlenecking that also improves energy efficiency helps twice.
  • Measurement matters. You can only claim what you can show. Sectional steam meters, fuel records and electricity sub-meters become compliance tools, not just nice-to-haves.

Your sector's monitoring and verification procedure defines exactly which emissions count, for example how purchased electricity and captive power are treated. Do the calculations in this article both ways if you are unsure.

How much CO2 is in a tonne of steam?

For a fuel-fired boiler:

tCO2t steam=hsteam−hfeedGCV×ηboiler×EFfuel

where h is enthalpy (kJ/kg), GCV the fuel's gross calorific value (kJ/kg), ηboiler the boiler efficiency on GCV basis, and EFfuel the CO2 per tonne of fuel.

Example (hypothetical)

  • Saturated steam at 10.5 bar(g): h≈2781 kJ/kg
  • Feed water at 80 °C: h≈335 kJ/kg
  • Indian coal, GCV 4,000 kcal/kg ≈ 16,700 kJ/kg; boiler efficiency 75%
  • Coal with about 40% carbon: EF≈0.40×44/12≈1.47 tCO2 per tonne of coal

Coal per t steam=2781−33516,700×0.75≈0.195 t

CO2 per t steam≈0.195×1.47≈0.29 t

So a plant using 10 t/h of steam for 8,000 hours a year emits around 23,000 tCO2 a year from steam alone. Every 1 t/h saved is worth roughly 2,300 tCO2 a year, as well as about 1,560 t of coal.

For reporting, use your own coal analysis, measured boiler efficiency and the emission factors your verifier accepts. For a quick check on steam conditions, use our steam table.

Where does the steam go?

In chemical, pharma, textile and effluent plants, the big steam users are usually:

EquipmentWhy it uses steamTypical share in plants that have it
Multiple-effect evaporators (MEE) for effluent or productLatent heat of evaporation, divided by steam economyOften the largest single user in ZLD plants
Distillation and solvent recovery columnsReboiler duty, driven by reflux ratioLarge in solvent-heavy pharma and agrochemicals
Agitated thin film dryers and other dryersDrying the final salt or productSignificant in ZLD trains
Reactor jackets and process heatingHeating batches, holding temperatureSpread across many users
Textile wet processingDyeing, washing, stentering (often thermal oil)Large in process houses
LossesFailed traps, poor insulation, lost condensate, flash steam ventedOften 10–20% of generation in older plants

Meter these first. Without sectional metering, plants usually guess wrong about where the steam goes.

Lever 1: raise evaporator steam economy

Evaporators are where design choices change steam use the most. Approximate steam economy (kg water evaporated per kg steam):

ConfigurationSteam economySteam per tonne of water evaporated
Single effectabout 0.9about 1.1 t
Double effectabout 1.7about 0.59 t
Triple effectabout 2.5about 0.40 t
Four effectabout 3.2–3.4about 0.30 t
Five effectabout 4.0about 0.25 t
Effects + TVR on first effectroughly one extra effect
MVRelectricity, 15–35 kWh per tonnesmall make-up steam only

Example: 4,000 kg/h of evaporation (hypothetical)

A ZLD plant evaporating 4,000 kg/h of water in a triple-effect MEE uses about 1.6 t/h of steam, around 0.46 tCO2 per hour at 0.29 tCO2/t.

  • Add a fourth effect: steam falls to about 1.2 t/h, saving about 0.4 t/h, roughly 900 tCO2 a year at 8,000 hours.
  • Convert to MVR: at 25 kWh per tonne, power is about 100 kW. At a grid factor of roughly 0.7 tCO2/MWh (use the latest CEA CO2 baseline database value), that is about 0.07 tCO2 per hour, against 0.46 for the steam. The saving is about 3,100 tCO2 a year, provided the feed suits MVR (low boiling point rise, manageable fouling).

Our articles on improving steam economy, MVR vs TVR and the MVR evaporator and multi-effect evaporator pages go into design detail. The evaporator cost comparison tool gives a first estimate of operating cost by configuration.

Lever 2: recover condensate and flash steam

Returning hot condensate to the boiler cuts the heat needed to raise feed water. Raising feed water from 30 °C to 90 °C saves about 250 kJ per kg of steam, roughly 10% of boiler fuel. Condensate is also clean, softened water, which reduces blowdown and treatment.

Where condensate is contaminated, as with process condensate from an MEE, its heat can still be recovered in a plate exchanger to preheat feed. See condensate heat recovery in ZLD plants.

When high-pressure condensate drops to a lower pressure, part of it flashes to steam. Collecting that in a flash vessel and using it in a low-pressure header avoids venting it. The flash steam calculator shows how much is available, and our article on flash vessel energy savings shows how to use it.

Lever 3: cut distillation reboiler duty

Reboiler duty is set mostly by reflux ratio and feed condition. Practical steps:

  1. Check the reflux ratio. Many columns run well above the minimum needed for specification because nobody has retuned them since commissioning. A 10% cut in reflux can give a similar cut in steam.
  2. Preheat the feed with the bottoms product or overhead vapour.
  3. Use overhead heat. Column overhead vapour can reboil another column running at lower pressure, or preheat feed. See waste heat recovery from column overheads.
  4. Consider vacuum or vapour recompression for close-boiling separations, where a heat pump can replace most of the reboiler steam.
  5. Check tray or packing condition. A damaged or fouled column needs more reflux for the same purity. Our distillation column guide covers diagnosis.

Lever 4: fix the losses

Low-capital fixes often deliver 5–15% of steam generation:

  • Steam traps. Survey every trap at least yearly. A failed-open trap on a 10 bar(g) line can waste several tonnes of steam a month.
  • Insulation. Bare valves, flanges and pipework lose heat continuously. Use the insulation heat loss calculator to prioritise.
  • Leaks and vents. Venting low-pressure steam to atmosphere is common when headers are not balanced.
  • Boiler tuning. Excess air, blowdown control and economiser cleaning all affect efficiency, and so tCO2 per tonne of steam.

How should a plant plan the work?

  1. Establish the baseline. Steam and fuel per section, per tonne of product, for 2023–24 and the current year.
  2. Rank users by tCO2 per year, not by steam alone.
  3. Do the low-capital fixes first: traps, insulation, condensate return, reflux tuning.
  4. Screen equipment upgrades with a simple table: tCO2 saved per year, capital cost in ₹ lakh, fuel saving per year and payback. An extra effect, TVR or MVR often pays back on fuel alone in two to four years, before any credit value.
  5. Install meters on each upgraded section so savings can be verified.
  6. Check side effects. MVR increases electrical load; extra effects increase footprint and cooling water demand; heat integration links units that used to run independently.

A note on suppliers and non-obligated plants

Many chemical and pharma plants are not obligated entities themselves, but they supply obligated customers or report under BRSR. Lower steam per tonne still cuts fuel cost, and customers increasingly ask suppliers for energy and emission data. The same levers apply.

Conclusion

For most Indian process plants facing CCTS targets, or just high fuel bills, the fastest emission cuts come from steam: better evaporator economy, MVR where the feed allows, condensate and flash steam recovery, tighter distillation operation and fixing losses. Send your steam balance and evaporator or column data to SEMCO and our process engineers will help you identify the largest savings.

Frequently asked questions

Which sectors have emission intensity targets under CCTS?

Targets were notified in October 2025 for aluminium, cement, chlor-alkali and pulp and paper, and in January 2026 for petroleum refineries, petrochemicals, textiles and secondary aluminium, covering 490 obligated entities in all according to the government's press release. Check the notification for your own plant's target.

How much CO2 does one tonne of steam from a coal boiler emit?

Roughly 0.25–0.35 tonne of CO2 per tonne of steam for a typical Indian coal-fired boiler, depending on coal quality, boiler efficiency and steam conditions. Calculate it from your own coal analysis and boiler efficiency for reporting.

Does switching an evaporator from steam to MVR reduce emissions?

Usually, yes, by a large margin. An MVR evaporator uses electricity instead of steam, typically 15–35 kWh per tonne of water evaporated. Even on the grid, that is a fraction of the CO2 from the steam a three- or four-effect evaporator needs, but check how your sector's rules count purchased electricity.

What can a plant do in the first year to lower emission intensity?

Meter steam by section, fix steam traps and insulation, return condensate, recover flash steam and tune evaporator and column operation. These low-capital steps often give 5–15% steam savings. Larger cuts need TVR, MVR, extra effects or heat integration.

Topic Tags:CCTSCarbon Credit Trading SchemeGHG Emission IntensitySteam EconomyMVREnergy Efficiency