In short
A sieve tray is a perforated deck with a weir and downcomer. It is the cheapest tray, has high capacity and lower pressure drop than bubble caps, and works well in fouling service with larger holes. Its weakness is turndown: below about half of design vapour rate it weeps. Choose sieve trays for steady continuous duty; choose bubble caps for wide load swings or very low liquid rates.
Quick answer. Choose sieve trays when the column runs at a steady load. They are the cheapest tray, give the most capacity for the diameter, have lower pressure drop than bubble caps and are easy to clean. Their limit is turndown, typically about 2:1, because liquid weeps through the holes at low vapour rates. If the load swings widely, or the liquid rate is very low, bubble caps or valve trays are the safer choice.
Sieve trays are the simplest tray there is: a flat perforated plate, an outlet weir and a downcomer. Vapour rises through the holes and bubbles through the liquid on the deck. Liquid flows across the tray, over the weir and down to the tray below.
That simplicity makes them cheap and robust. It also means there is nothing to stop liquid draining through the holes when the vapour rate falls. Most of sieve tray design is about setting the hole area, weir and downcomer so that the tray neither floods at high load nor weeps at low load.
This guide works through the design steps with a worked example. For a side-by-side comparison of all three tray types, see bubble cap vs sieve vs valve trays.
Sieve or bubble cap: a decision guide
| If your column… | Choose | Why |
|---|---|---|
| Runs continuously at 60–110% of design load | Sieve | Cheapest, high capacity, efficiency is good in this range |
| Has fouling or polymerising feed | Sieve, 10–13 mm holes | Few places for deposits; easy to clean |
| Runs in batch mode with boil-up from 20% to 100% | Bubble cap (or valve) | Sieve trays weep at low load |
| Has very low liquid rates (high reflux ratio at small capacity, absorbers with little solvent) | Bubble cap | Caps hold a liquid seal even with little liquid |
| Must not drain liquid at low load (reactive distillation, long residence time on the tray) | Bubble cap | Risers prevent liquid draining through |
| Is under vacuum and pressure drop is critical | Sieve if trays are needed, often packing | Bubble caps have the highest pressure drop |
| Needs moderate turndown at moderate cost | Valve tray | Turndown of about 4:1 at a cost close to sieve |
Relative installed tray cost is often quoted as sieve 1.0, valve 1.0–1.2 and bubble cap 2–3. On a column with 30 or 40 trays, that difference is large. For whether trays are the right choice at all, see packed column vs tray column.
What are the main design parameters?
These are typical starting values for a sieve tray. They are adjusted during the hydraulic check.
| Parameter | Typical range | Notes |
|---|---|---|
| Tray spacing | 450–600 mm (300 mm in small columns) | Larger spacing allows higher vapour load |
| Hole diameter | 5–6 mm clean, 10–13 mm fouling | Larger holes weep more and entrain less |
| Hole area / active area | 8–12% | Set by pitch; lower area improves turndown |
| Hole pitch | 2.5–5 hole diameters, triangular | 3 × diameter gives about 10% hole area |
| Deck thickness | 2–3 mm SS, about 0.2–0.4 of hole diameter | Thicker decks need larger holes |
| Outlet weir height | 40–90 mm, often 50 mm | Lower under vacuum, higher for longer contact |
| Downcomer area | 10–15% of column area each | Minimum about 8% |
| Downcomer clearance | Weir height minus 5–12 mm | Keeps a liquid seal on the downcomer |
The hole area follows from the pitch. For holes of diameter dh on a triangular pitch p:
AhAp=0.907(dhp)2
So a pitch of 3dh gives 0.907/9≈10%, and 3.5dh gives about 7.4%.
Step 1: Find the flooding velocity
The usual method is Fair's correlation. First the flow parameter:
FLV=LV√ρVρL
with L and V as mass flows. Read the capacity factor K1 for your tray spacing and FLV from the standard Fair chart (for 600 mm spacing at low FLV it is roughly 0.10–0.11 m/s). Then:
uf=K1(σ20)0.2√ρL−ρVρV
where σ is the surface tension in mN/m. Design at 75–85% of flooding for non-foaming systems, lower for foaming ones.
Step 2: Set the column diameter
The net area An (column area minus one downcomer) carries the vapour:
An=QV0.8 uf Ac=An1−Ad/Ac
Round the diameter up to a standard size and recheck the percentage of flooding.
Step 3: Check weeping at minimum load
Weeping starts when the vapour velocity through the holes falls below a minimum. A widely used estimate is:
uh,min=K2−0.90 (25.4−dh)√ρV
with dh in mm and uh,min in m/s. K2 depends on the clear liquid height on the deck, hw+how, and is about 30 for typical weirs (read it from the standard weep-point chart). The crest over the weir, in mm of liquid, is:
how=750(LwρL lw)2/3
where Lw is the liquid flow in kg/s and lw is the weir length in m. The actual hole velocity at the lowest expected vapour rate must stay above uh,min.
Step 4: Pressure drop
Total pressure drop per tray, in mm of liquid:
ht=hd+(hw+how)+hr
Dry plate drop and residual head:
hd=51(uhC0)2ρVρL hr=12.5×103ρL
C0 is the orifice coefficient, about 0.72–0.85 depending on deck thickness and hole area.
Step 5: Downcomer backup and residence time
Liquid in the downcomer has to rise high enough to overcome the pressure drop of the tray above. Backup:
hb=(hw+how)+ht+hdc hdc=166(LwdρLAm)2
Am is the smaller of the downcomer area and the clearance area under the downcomer. Keep hb below half of (tray spacing + weir height), and keep the liquid residence time in the downcomer above about 3 seconds so vapour can separate.
Worked example: a 700 mm sieve tray section
A hypothetical continuous solvent recovery column, top section, at atmospheric pressure:
- Vapour 2,500 kg/h, density 1.10 kg/m³
- Liquid 1,800 kg/h, density 750 kg/m³, surface tension 20 mN/m
- Tray spacing 600 mm, 6 mm holes in a 2 mm SS deck, weir 50 mm
- Downcomer area 12% of column area, hole area 10% of active area
Flooding. FLV=(1,800/2,500)√1.10/750=0.028. Take K1=0.10 m/s.
uf=0.10√750−1.11.1≈2.61 m/s
Diameter. Vapour flow is 2,500/3,600/1.10=0.631 m³/s. At 80% of flooding the net area is 0.302 m², the column area 0.344 m², and the diameter 0.66 m. Round up to 700 mm: column area 0.385 m², net area 0.339 m², which runs at about 71% of flooding.
Weir and crest. Weir length about 0.76 × D = 0.53 m. Crest at full liquid load is about 8.7 mm, and at 60% load about 6.2 mm.
Pressure drop. Active area 0.292 m², hole area 0.029 m², hole velocity 21.6 m/s. With C0=0.75:
| Term | Value, mm liquid |
|---|---|
| Dry plate, hd | 62 |
| Weir + crest, hw+how | 59 |
| Residual, hr | 17 |
| Total per tray | about 137 (≈ 1.0 kPa) |
Downcomer. With a 40 mm clearance, the backup is about 196 mm, well under the 325 mm limit. Residence time is about 14 s. Both fine.
Weeping. With K2≈30.4 and 6 mm holes:
uh,min=30.4−0.90(25.4−6)√1.10≈12.3 m/s
At 60% of design vapour rate the hole velocity is 13.0 m/s, just above the limit. At 50% it is 10.8 m/s, so the tray weeps. This tray works from about 57% to about 120% of design load (up to 85% flooding): a turndown of a little over 2:1.
Trading pressure drop for turndown
Opening the pitch to give 8% hole area raises the hole velocity. Weeping now starts at about 46% of design load, which gives a turndown of about 2.6:1. The cost is a higher dry plate drop (about 97 mm instead of 62), so the total rises to about 171 mm of liquid per tray. Downcomer backup rises to about 230 mm, still acceptable.
That is the basic sieve tray trade-off: less hole area gives more turndown and more pressure drop. If you need much more than 3:1, a sieve tray is the wrong tray.
Check the numbers yourself. Use this as a method, not a design. Real columns need full tray rating for each section (top and bottom loads differ), physical properties at tray conditions and a check for foaming. The engineering unit converter helps when vendor data comes in mixed units.
Myths and facts about sieve trays
| Myth | Fact |
|---|---|
| "Sieve trays are less efficient than bubble caps." | Near design load, sieve and valve trays have efficiency similar to or better than bubble caps. They lose efficiency only when they weep. |
| "Sieve trays cannot handle dirty service." | With 10–13 mm holes they are among the most fouling-tolerant trays, because there are no caps or valves to stick. |
| "Bigger holes always mean less pressure drop." | Pressure drop depends on hole velocity, set by total hole area, not hole size. Bigger holes at the same area mainly increase weeping. |
| "Bubble caps are obsolete." | They are still the right choice for wide turndown, very low liquid rates and services where liquid must stay on the tray. |
| "A column that floods needs bigger trays." | Many floods start in the downcomer, from foaming or a small clearance. Check downcomer backup first. |
Common problems in operation
- Weeping at low throughput. Separation falls when the plant runs below about half load. Fix by blanking some holes, adding blanking strips at the tray edge, or changing to valve trays. See weeping and flooding in distillation columns.
- Flooding at high load or with foaming feed. Check downcomer backup and residence time; use a foaming (system) factor in design.
- Plugged holes. Small holes in polymerising or salting service block quickly. Use larger holes from the start.
- Corroded holes. In aggressive service, holes enlarge, hole area rises and the tray weeps. Choose deck metallurgy for the service, not just the shell.
- Out-of-level trays. Sieve trays need a level deck, typically within ±3 mm across the diameter for small columns, or liquid takes the low side and vapour the high side. Check levelness during installation.
- Damage from pressure surges. A slug of water into a hot column can lift trays. Use proper tray clamping and avoid sudden water ingress.
Buyer's checklist for a sieve tray column
- Vapour and liquid loads for each section, at maximum and minimum operating rates
- Physical properties at tray conditions: densities, surface tension, viscosity
- Foaming tendency, fouling or polymerising components, solids
- Required turndown, and how often the column runs at minimum load
- Allowable pressure drop (critical under vacuum)
- Number of stages from simulation and assumed tray efficiency; see how to determine the number of stages
- Hole size, hole area, weir height and downcomer area, with a hydraulic rating for each section
- Deck and downcomer metallurgy, thickness and clamping detail
- Manway spacing, tray removal and levelness tolerance
Bottom line
Sieve trays are the default for continuous columns that run at a steady load: low cost, high capacity, low pressure drop and easy cleaning. Size them from Fair's flooding correlation, check weeping at the lowest real load and check downcomer backup at the highest. When the load swings by more than about 2–3:1, or the liquid rate is very low, use bubble cap trays or valve trays instead.
SEMCO designs and builds tray and packed distillation columns, including high vacuum distillation systems and solvent recovery plants. Send us your vapour and liquid loads and required turndown, and we will help you choose and size the right tray.
Frequently asked questions
When is a sieve tray better than a bubble cap tray?
When the column runs at a fairly steady load, such as a continuous solvent recovery or product column. Sieve trays cost much less, give more capacity for the same diameter, have lower pressure drop and are easier to clean. Bubble caps are better when the vapour rate swings widely, the liquid rate is very low, or liquid must not drain through the tray at low load.
What is the turndown ratio of a sieve tray?
Typically about 2:1, sometimes up to 3:1 with a lower hole area. Below that, liquid weeps through the holes and tray efficiency falls. Bubble cap trays commonly turn down 4–5:1 or more, and valve trays sit in between.
What hole size and hole area are used on sieve trays?
Holes of 5–6 mm are common for clean service and 10–13 mm for fouling or dirty service. Hole area is usually 8–12% of the active area, set by the hole-to-hole pitch: with a triangular pitch of three hole diameters it is about 10%.
What tray spacing is used for sieve tray columns?
Usually 450–600 mm for columns above about 1 m diameter, and down to 300 mm in small columns where manways are not needed on every tray. Larger spacing raises the flooding limit and makes maintenance easier, at the cost of a taller column.
Why does a sieve tray column lose efficiency at low throughput?
At low vapour rates the gas no longer holds the liquid on the deck, so liquid leaks through the holes (weeping) instead of flowing across the tray and over the weir. That liquid bypasses the contact zone, so separation suffers. The cure is a design with lower hole area, or a valve or bubble cap tray if low-load operation is common.